<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>7015</ErrorNumber>
<ErrorFamily>Carriage</ErrorFamily>
<ErrorMessage>
CARRIAGE: Head Stage is at it's away position, unsafe to move carriage
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Either the sys hi parameter is set to 0 or the ale is not coming out of reset properly
or the ale lca is not downloading properly upon reset or the mpe lca is not downloading
properly after reset.  Replace the MPE or ALE if the the sys hi parameter is set to 1.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Click on RESUME. The platesetter should recover.  If it does not, please turn the power
to the output machine off and on again.  Please contact Creo Service to report
this error.
</text></DescriptionText>
</OperatorAction>
<Cause>
Either the sys hi parameter is set to 0 or the ale is not coming out of reset properly
or the ale lca is not downloading properly upon reset or the mpe lca is not downloading
properly after reset.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/sys_cfg_hi.xml</LinkAddress><LinkTitle>NVS: sys hi</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:29 2008 PST
</Updated>
<Links>
</Links>
</Error>